Custom electrical enclosure back panel: mounting on the enclosure studs, a hole grid for DIN rails and wire ducts, optional pressed-in PEM nuts or studs.
Price without signing up · Made in Quebec · $49 minimum order
Start from a common size
A preset fills in the model; you then change each dimension in the application.
10 sizes
Suggested
Saginaw)
For a 12 × 10 in enclosure (Hoffman
11 × 9 in panel, four studs at 10.25 × 8.25 in centres, 0.25 in holes: the dimensions of Saginaw SCE-12P10; same spacing as Hoffman A12P10, whose panel is 10.75 × 8.88 in.
Width
9″
Height
11″
Corner radius
0.125″
Stud H spacing
8.25″
All values
Stud V spacing: 10.25″ Fixing hole Ø: 0.25″ Slot travel: 0″ 6 studs: no Grid columns: 0 Grid rows: 0 Grid H pitch: 2.5″ Grid V pitch: 2″ Grid hole Ø: 0.221″ PEM inserts: None: plain holes
33 × 21 in panel, six studs (one more midway up each side) at 31.25 × 19.25 in centres, 0.50 in holes: the dimensions of Hoffman A36P24, Saginaw SCE-36P24 and Hammond 1418N4L6.
33 × 27 in panel, six studs (one more midway up each side) at 31.25 × 25.25 in centres, 0.50 in holes: the dimensions of Hoffman A36P30, Saginaw SCE-36P30 and Hammond 1418N4M8.
The back panel mounts at the back of an electrical enclosure, on the studs provided for
it. DIN rails, wire ducts, terminal blocks and components are fitted to it at the bench,
before it goes into the enclosure.
The model carries two things: the mounting holes, one per enclosure stud (four, or six
on large enclosures), and a grid of holes for the rails and ducts, centred on the
panel.
Mounting in the enclosure
The four holes are placed by the horizontal and vertical spacing of the enclosure
studs, measured centre to centre; they are centred on the panel. A non-zero slot
travel turns the holes into vertical slots: the panel then hangs on its upper
studs and is adjusted in height before tightening.
Enclosures 36 in tall have six studs: one more midway up each vertical
side. Tick one stud midway up each vertical side for them.
Take the spacing from your enclosure, or from its maker's drawing, together with the
panel size that drawing gives.
Common enclosure sizes
The single-door wall-mount enclosures of Hoffman (A-xxPxx panels), Saginaw (SCE-xxPxx)
and Hammond (1418N4 series) share the same template, read on their drawings: the panel is
the enclosure size minus 3 in, and the studs are spaced at the enclosure size minus
4.75 in. Each row is a preset; the panel is plain, add the grid you need.
Enclosure (H × W)
Panel (H × W)
Stud spacing (H × W)
Studs
Holes
Makers
12 × 10 in
11 × 9 in
10.25 × 8.25 in
4
0.25 in
Hoffman, Saginaw
16 × 12 in
13 × 9 in
11.25 × 7.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
16 × 16 in
13 × 13 in
11.25 × 11.25 in
4
0.50 in
Hoffman, Hammond
20 × 16 in
17 × 13 in
15.25 × 11.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
20 × 20 in
17 × 17 in
15.25 × 15.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
24 × 20 in
21 × 17 in
19.25 × 15.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
24 × 24 in
21 × 21 in
19.25 × 19.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
30 × 24 in
27 × 21 in
25.25 × 19.25 in
4
0.50 in
Hoffman, Saginaw, Hammond
36 × 24 in
33 × 21 in
31.25 × 19.25 in
6
0.50 in
Hoffman, Saginaw, Hammond
36 × 30 in
33 × 27 in
31.25 × 25.25 in
6
0.50 in
Hoffman, Saginaw, Hammond
The 12 × 10 in box is the exception: its panel and holes follow the Saginaw SCE-12P10
drawing. Hoffman's (A12P10) is 10.75 × 8.88 in, with the same spacing. Hoffman Concept
(CSD) and Wiegmann N412 enclosures have a spacing of their own and are not in this table.
Measure yours before ordering. None of these drawings gives the stud thread.
The grid for rails and ducts
Columns, rows and two pitches, measured centre to centre; the grid is centred on the
panel. With plain holes, the default diameter, 0.221 in, is the clearance for a #10
screw.
Nuts or studs fitted in advance
Pick them in the Grid - PEM inserts fitted field. The model then cuts
every grid hole to the exact diameter the insert asks for, and we press the inserts into
the panel before it ships. The mounting holes stay plain: they take the enclosure
studs.
Nothing is locked in: at the Operations step, every insert placed by
the model shows up already selected, and you can change or remove it hole by hole, from
the selection offered for your material. The price of the inserts is added to the
part.
Screws and nuts are not supplied. A pressed-in nut takes a screw of
its own thread (M5 for an M5 nut); a stud takes a nut of its own thread. Their length
depends on the rail or duct being fixed.
Why a pressed-in insert
No access to the back. Once the panel is in the enclosure, its back
is against the enclosure wall: no way to hold a nut there. With pressed-in nuts, a rail
is added or moved from the front, with the panel in place.
Instead of tapping thin sheet. Thin sheet only offers a few threads,
which strip easily after repeated dismantling. The insert brings a full steel
thread.
Inserts offered on this model
Insert
Part number (steel, aluminium)
Hole cut
Centre to edge, at least
Minimum sheet
M4 nut
S-M4-0
0.214 in (5.4 mm)
0.272 in (6.9 mm)
0.8 mm
M5 nut
SS-M5-0
0.250 in (6.4 mm)
0.280 in (7.1 mm)
0.8 mm
M6 nut
S-M6-0
0.348 in (8.8 mm)
0.339 in (8.6 mm)
1.2 mm
#8-32 nut
S-832-1
0.213 in (5.4 mm)
0.270 in (6.9 mm)
0.040 in
#10-32 nut
SS-032-1
0.250 in (6.4 mm)
0.280 in (7.1 mm)
0.040 in
1/4-20 nut
S-0420-1
0.344 in (8.7 mm)
0.340 in (8.6 mm)
0.056 in
M5 × 12 mm stud
FH-M5-12
0.197 in (5.0 mm)
0.283 in (7.2 mm)
1 mm
#10-32 × 1/2 in stud
FH-032-8
0.189 in (4.8 mm)
0.281 in (7.1 mm)
0.040 in
The minimum sheet thickness is the manufacturer's; the material suggested for this
model (12 gauge steel, 0.105 in) exceeds all of them. On stainless steel, the insert is
replaced by its stainless equivalent when one exists; otherwise it is removed, and the
Operations step tells you so.
What the model refuses, and why
Zero or negative dimensions.
A mounting pattern or grid wider than the panel. The model gives the
panel size the requested spacing would need, slots included.
A hole or slot too close to the edge. At least 1/16 in of material
between a hole and the edge.
Two holes too close together. At least 1/16 in of material between
two holes; a grid landing on the mounting holes is refused.
An insert too close to an edge or a mounting hole. Each insert needs
a minimum distance from its centre to the nearest edge (table above). The model names
the insert, the distance and the minimum.
Laseo is not affiliated with Hoffman, Saginaw and Hammond, nor sponsored or endorsed by Hoffman, Saginaw and Hammond. Brand names are used only to indicate that the part is compatible.